Environmental Monitoring System

Vutlan · monitoring units, extensions, sensors, software

Environmental Monitoring System

One monitoring unit per room, extended with the boards and sensors that room actually needs — from a single office cabinet to a full data hall.

UNITS3 MODELS

Environmental Monitoring Units

BASE UNIT

Pick the base unit by room size; every model is managed from the same web interface.

VT225t — Office Monitoring UnitThe VT225 / Office Monitoring Unit can be used for remote environmental monitoring in small offices.
Small office
VT825
VT825 — Data Center Monitoring UnitThe VT825 / Data Center Monitoring Unit can be used for remote environmental monitoring in data centers.
Data center
VT335
VT335t — IT Monitoring UnitThe VT335 / IT Room Monitoring Unit can be used for remote environmental monitoring in small IT rooms.
IT room
EXTENSIONS8 BOARDS

Extensions

EXPANSION

Add relay outputs, dry contacts, Modbus, cellular or card readers without changing the base unit.

VT12
VT12 — Relay ModuleVT12 Relay Module is a dual-channel switching unit designed to turn on/off loads. It can be connected to the dry contacts outputs of VT855 and VT336 Vutlan monitoring units to turn on/off loads with current up to 1A, when the device’s Dry contact output is triggered.
2 channels · up to 1A
VT11
VT11 — Relay OutputThe VT11 Relay output is designed to turn on/off loads. It can be connected to the 12VDC relay output of any Vutlan monitoring device to turn on/off when the device’s 12V output is triggered.
12 VDC triggered
VT32 — Dry Contacts Board for VT440An extension board “VT32 / dry contacts board”.
Expands VT440 to 64
VT485m — Modbus RTU ExtensionThe VT485M / Modbus expansion board transmits measured data from Modbus devices to the Vutlan monitoring device.
Modbus RTU
VT7670 — 4G ModemThe VT7670 / 4G modem supports receiving and sending SMS messages via 2G, as well as providing Ethernet connectivity over LTE (4G).
SMS · LTE (4G)
VT485r
VT485r — OSDP Reader BoardThe VT485r is an extension PCB board that allows for the connection of readers and keypads that support the OSDP protocol. This board is compatible with Vutlan monitoring systems, including VT335t, VT336t, VT825t, and VT855t.
VT335t · VT336t · VT825t · VT855t
VT440 — Dry Contacts UnitThe VT440 expansion module increases the number of dry contacts that can be connected to any Vutlan monitoring device. Each VT440 module has 32 dry contacts, which can be expanded to 64 using the “VT32 / Dry Contact Board”.
32 contacts → 64 with VT32
VT408
VT408 — Sensor Extension UnitThe VT408 expansion module increases the number of analog sensors that can be connected to any Vutlan monitoring device.
Analog expansion
SENSORS10 TYPES

Sensors

MEASUREMENT

Temperature, water, current, dust, vibration, airflow and access — measured at the point where it matters.

VT500 — Temperature SensorThe VT500 Temperature sensor is designed for indoor temperature measurements, providing an accuracy of ± 0.25 °C at room temperature.
±0.25 °C at room temp
VT501
VT501 — Outdoor Temperature SensorThe VT501 Temperature sensor is designed for outdoor temperature measurements, providing an accuracy of ± 0.25 °C.
±0.25 °C
VT594
VT594 — BMS Leak Water SensorThe VT594 Water Leak Sensor is designed for integration with Building Management Systems (BMS) to provide continuous monitoring for water leaks by measuring the resistance drop in the connected WLC Leak Detection Cable. This sensor requires a WLC Leak Detection Cable, which must be ordered separately and is available in a variety of lengths.
BMS integration
VT580 — Dust Particles SensorThe VT580 Dust particle sensor is designed to monitor air quality and pollution levels. Its measurement principle is based on laser scattering. The sensor provides accurate measurements from the moment it is first turned on and throughout its service life, which is more than ten years.
Service life >10 years
HAT-100Q1 — AC Current TransducerThe HAT-100Q1 is a simple open-loop ammeter capable of measuring AC current in the 0-100A range. It connects to the monitoring system via the VT407 transceiver.
0–100 A AC
HOS-100Q1 — DC Current AmmeterThe HOS-100Q1 is a simple open-loop DC ammeter capable of measuring DC currents in the range of ±100A. It connects to the monitoring system via the VT406 transceiver.
±100 A DC
VT420 — Current Loop ConverterThe VT420 / 4-20mA current monitor converts measured DC current from different sensors into a format compatible with the Vutlan monitoring system. The system interface allows you to assign the sensor and introduce the function data conversion.
4–20 mA
VT530
VT530 — Access SensorThe VT530 Access Sensor is essential for access control and is designed to monitor the status of doors and windows (open or closed). It consists of two parts: a magnet and a sensor.
Access control
VT540
VT540 — Vibration SensorThe VT540 Vibration Sensor is designed to detect and monitor vibrations when installed on surfaces such as walls or windows.
Surface mount
VT550
VT550 — AnemometerThe VT550 Anemometer is designed to measure air flow velocity generated by devices such as air conditioners, HVAC systems, fans and ventilation systems. It monitors air flow in the range of 0 to 3 m/s.
0–3 m/s
SOFTWAREMANAGE
Included

User Web Interface

The Vutlan web interface provides users with a powerful and intuitive platform to manage and monitor a wide range of devices, sensors, and environmental systems. It’s designed for ease of use while offering advanced features for real-time control and automation.

Licensed

Duplicator License

The Duplicator program is a management tool specifically designed for handling the configuration and firmware updates of multiple Vutlan monitoring devices.